  P2Y12 (Plavix) Specimen Type:
  also known as Plavix Assay

Blood


POINT OF CARE TESTING

Specimen requirements: Point of Care
Unit of measure: PRU and % inhibition
Ideal sample: Whole blood collected in the appropriate Greiner Tube. Collect 6-10 hours after Plavix dose. Assay 10 minutes to 4 hours of collection.
Absolute minimum amount: 2.7 mL draw size sample
Method of collection: N/A
Transportation: N/A
Label instructions: N/A
Request test on form: N/A
Stat frequency: N/A
Stat turn around time: N/A
Routine frequency: N/A
Must be in by: N/A
Routine turn around time: N/A
Deliver the specimen to : NA : NA
Deliver the specimen to : NA : NA
Scheduling requirements : N/A
Method: Increase of light transmittance due to the agglutination of fibrinogen coated microparticle beads in proportion the number of unblocked platelet gp Iiba/IIIa receptors.
Special Instructions: Use the Accumetrics VerifyNow P2Y12 System Instrument and VerifyNow Aspirin Assay Devices. Refer to the procedure "ACCUMETRICS VERIFYNOW P2Y12 ASPIRIN ASSAY" located at the patient care area site.
CyberLAB abbreviation: N/A
CyberLAB code: N/A