WELCOME TO UCSD LABORATORY SERVICES GUIDE  
cms.ucsd.edu/labref/default.asp
 #   A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
  Raji Cell Specimen Type:
  also known as Raji Cell Immune Complex Detection

Blood


SCRAP

Specimen requirements: 3 mL Red Stopper; Plain
  or: 7 mL Red Stopper; Plain
  or: SST
Reference ranges:
CATEGORY LOW   HIGH   UNITS   QUALITATIVE  
Negative 0 25 uge/mL N/A
Positive N/A >25 uge/mL N/A
Unit of measure: uge/mL
Ideal sample: 4 mL
Absolute minimum amount: .0.5 mL serum
Method of collection: N/A
Transportation: Transport to the Laboratory immediately.
Label instructions: N/A
Request test on form: "Write in" MULTI LABS [Chem/Hem/UA/Tox/BB/Rheum] ( 151-104 )
Order/entry screen(s):  N/A
Stat frequency: N/A
Stat turn around time: N/A
Routine frequency: Tueday and Friday
Must be in by: N/A
Routine turn around time: 7-10 days
For Hillcrest deliver to: SCRAP : Specimen Central Receiving and
  Processing, room 2-117
For Thornton deliver to: Chemistry : Processing Desk, 1st floor, Hospital,
  room 1-013
This test is sent to : ARUP - Associated Regional & University
Scheduling requirements : N/A
Method: Flow Cytometry
Special Instructions: N/A
  Results are available on a Chart Copy
  Results are Quantitative
CyberLAB abbreviation: RAJI
CyberLAB code: 9104
Lab Processing Instructions: Let sample stand for 2 hours then separate within 1 hour and freeze immediately. Freeze specimen after processing. Critical frozen.